bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

6 RA Replacing Control Unit (DME)|Page 426 > < 5 RA Replacing Pulse Generator On Exhaust Camshaft (N54)
Page 1
background image

12 14 550

Replacing control unit (DME) 

Necessary preliminary tasks:

Switch off ignition

Disconnect battery

Remove microfilter housing

Important!

Follow instructions for removing and installing control units

Important!

Read and comply with notes on protection against
electrostatic damage (ESD protection).

Replacement:

Carry out programming/coding

Carry out injector quantity adjustment (description at end of

instruction)

Important!

It is absolutely essential to read out the fault memory with the
MoDiC or the BMW DIS and to create a fault memory printout.

Switch off ignition.

RA  Replacing control unit (DME)

BMW AG - TIS

19.02.2013  19:25

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

6 RA Replacing Control Unit (DME)|Page 426 > < 5 RA Replacing Pulse Generator On Exhaust Camshaft (N54)