3 Series E91 320i (N43) TOUR
•
When using special tool 11 9 150 in conjunction with
special tool 11 7 030 , 47 Nm on torque wrench scale
corresponds to an actual tightening torque of 50 Nm.
•
The threads of new oxygen monitor sensors are already
coated with Never Seez Compound.
•
If an oxygen monitor sensor is reused, only apply a thin and
uniform coat of Never Seez Compound (refer
to BMW Parts Service) to thread.
•
Oxygen monitor sensor section projecting into exhaust
system branch must not be cleaned or come into contact with
lubricant.
•
Cover oxygen monitor sensor when applying underseal.
Check function of DME.
RA Replacing lambda oxygen monitor sensor (N43)
BMW AG - TIS
24.01.2013 07:57
Issue status (12/2007) Valid only until next DVD is issued
Copyright