bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

5 RA Checking Fuel Tank And Tank Venting System For Leaks With Tank Leakage Diagnosis > < 4 RA Checking Fuel Tank And Tank Ventilation System For Leaks|Page 583
Page 3
background image

1. 

Select "Measurement" function on Diagnosis and Information

System (DIS). 

2. 

Using pressure regulator on special tool 16 1 171 , increase

pressure by 0.20 bar.

3. 

Connect special tool 16 1 174  to fast-release coupling of

special tool 16 1 171 .

4. 

Wait until the value at the Diagnosis and Information System

has levelled out.

5. 

Using pressure regulator on special tool 16 1 171 , reset

gauge pressure in fuel tank to 0.20 bar.

Important!

Do not under any circumstances increase pressure by more
than 0.30 bar as this would result in damage to the fuel tank
and venting system.

Using special tool 13 3 010 , disconnect delivery line from
special tool 16 1 171  to fuel filler neck.

Allow a rest period of approx. 20 sec.

Read off and note down starting pressure value.

Wait approx. 120 sec.

Read off final pressure value and compare with starting pressure
value.

Measurement evaluation:

Pressure drop up to 0.01 bar: 

System OK

Pressure drop over 0.02 bar:

System leaking beyond permitted levels

If the system is leaking, a leak test must be carried out and the
defective components replaced.

RA  Checking fuel tank and tank ventilation system for leaks

BMW AG - TIS

21.02.2013  01:08

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 3 -

5 RA Checking Fuel Tank And Tank Venting System For Leaks With Tank Leakage Diagnosis > < 4 RA Checking Fuel Tank And Tank Ventilation System For Leaks|Page 583