Important!

Mechatronics can be destroyed by static discharges.
Therefore the contacts inside the plug must not be touched.
Insert special tool immediately after work step.

Unscrew plug (1) and disconnect.

Insert special tool 24 2 390  in sealing sleeve (1).

Remove transmission oil sump.

Unlock sealing sleeve with slide (1).