bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

4 RA Removing And Installing Or Replacing Expansion Valve|Page 2703 > < 3 RA Cleaning Evaporator|Page 2701
Page 1
background image

64 51 520

Removing and installing or replacing
expansion valve

Warning!

Risk of injury!

Refrigerant circuit is under high pressure!

Follow safety instructions for handling R 134a refrigerant .

Avoid contact with refrigerant and refrigerant oil.

Follow safety instructions for handling refrigerant oil.

Important!

Risk of damage!

Restart engine only when A/C system has been correctly
filled.

Follow instructions for opening and replacing parts in
refrigerant circuit!

Note:

If A/C system is opened for more than 24 hours:Replace desiccant
insert for A/C system

Necessary preliminary tasks:

Drawing off, evacuating and filling the A/C system are not

included in the time value given for this work operation

Remove lower section of microfilter housing

Release screws (1, 2), disconnect refrigerant lines and lay to one
side.

Installation:

Replace all sealing rings and moisten with refrigerant oil.

Tightening torque  64 53 2AZ

.

RA  Removing and installing or replacing expansion valve

BMW AG - TIS

21.02.2013  15:39

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -