3 Series E92 320i (N43) COUPE
Disconnect plug connection (1).
Unfasten hose clip (2).
Release screws (3).
Tightening torque: 11 51 1/ 2AZ
.
Remove coolant pump (4) downwards.
Installation:
If the coolant pump is to be reused, it must be mechanically
rotated once (breakaway torque at impellers).
One coolant pump rotation will be sufficient.
Assemble engine.
Venting instructions must be observed without fail.
RA Removing and installing/replacing coolant pump (N43)
BMW AG - TIS
21.01.2013 20:24
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 2 -