Necessary preliminary tasks:

Remove heat shields.

Support automatic transmission with hydraulic lifter.

Remove transmission cross-member.

Grip clamping sleeve (1).

 Loosen nut (2).

Detach retainer (3) towards bottom using a screwdriver.

Pull cable (4) out of holder.

Installation:

Adjust selector lever.

Important!

Mechatronics can be destroyed by static discharges.
Therefore the contacts inside the plug must not be touched.
Insert special tool immediately after work step.

Unscrew plug (1) and disconnect.

Insert special tool 24 2 390  in sealing sleeve (1).