13 62 602

Replacing pulse generator on right inlet
camshaft (S65)

(cylinder bank 1 to 4)

Necessary preliminary tasks:

Read out fault memory of DME control unit; if necessary,

work through test schedules

Switch off ignition

Release and raise coolant expansion tank. Do not kink

hoses.

Remove right ignition coil cover

Release plug connector (1) and pull off.

Release screw.

Remove pulse generator (2).

Installation:

Replace sealing ring and coat with antiseize agent.

Tightening torque,  13 62 5AZ

Note:

Now clear the fault memory.