bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

1 RA Replacing Battery Positive Lead (between Starter And B- Terminal) (S65)|Page 522 > < 2 RA Replacing Solenoid Switch
Page 1
background image

12 42 510

Replacing battery positive lead (between
starter and B+ terminal) (S65)

Read fault memory. Switch off ignition.

Observe safety instructions for handling vehicle battery.

Observe instructions for disconnecting and connecting battery.

Disconnect battery negative lead from battery and lay to one side.

Necessary preliminary tasks:

Remove intake air manifold.

Release and raise cable duct for engine wiring harness; refer to 
Removing engine wiring harness

Release nut (2) on B+ lead.

Remove B+ leads.

Installation:

Tightening torque,  12 41 1AZ

Release clamp for B+ lead on cylinder no. 4.

Unclip lead from cable holders.

RA  Replacing battery positive lead (between starter and B+ terminal) (S65)

BMW AG - TIS

21.02.2013  19:24

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -