3 Series E92 M3 (S65) COUPE
Important!
The following venting procedure is necessary e.g. when a part
is replaced in the cooling system or when the cooling system
is refilled.
Only when filling!
•
Perform filling operation slowly.
•
Set heater to maximum temperature and turn fan down to
lowest speed.
•
Start engine and run at idle speed.
•
Fill coolant expansion tank with 250 ml above max. (250 ml
correspond to A=18 mm).
•
Run engine for 15 mins.
•
Cooling system vents itself.
•
Coolant level must drop to marking.
•
If necessary, correct coolant level.
•
Close cap on expansion tank.
Note:
If necessary, check cooling system for water leaks.
RA Venting cooling system and checking for water leaks (S65)
BMW AG - TIS
21.02.2013 20:21
Issue status (12/2007) Valid only until next DVD is issued
Copyright