3 Series E93 320i (N46T) CONVER
Unlock lug (1) in direction of arrow, slide plug (2) out of DME
plug (3).
Release screws.
Remove cable duct (1).
Work step
Note:
Release connector from fuel rail and remove
Cut through cable ties.
Release connector at actuator motor for eccentric shaft and unplug
Unlock plug on eccentric shaft sensor and disconnect
Release connector from ignition coils and unplug
Release connector from ground connection
Unlock plug on both solenoid valves and disconnect
Release connector from pulse generator for intake camshaft and unplug
Release connector from pulse generator for exhaust camshaft and unplug
Unlock plug on coolant thermostat and disconnect
Cut through cable tie.
Remove wiring harness section.
Note:
Check stored fault messages.
Now clear the fault memory.
RA Replacing wiring harness section for ignition coil (N46)
BMW AG - TIS
23.01.2013 18:41
Issue status (12/2007) Valid only until next DVD is issued