bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

14 Housing Cover > < 1 RA Removing And Installing, Sealing Or Replacing Oil Sump (N52K)
Page 2
background image

Unclip electric leads (2) of oxygen monitor sensors from
holder (3).

Disconnect plug connections (1) of oxygen monitor sensors and
lay to one side.

Release bolts (5) on transmission.

Tightening torque  11 13 7AZ

.

Disconnect plug connection (4) on oil level sensor.

Lay holder (3) to one side.

Detach return hose (2).

Important!

For vehicles with optional extra SA205 (automatic
transmission), bolts of different lengths are installed for
mounting the oil sump.

Observe different tightening torques.

Release screws along line (1).

For vehicles with optional extra SA205 (automatic transmission):

Tightening torque  11 13 2AZ

.

Tightening torque  11 13 3AZ

.

For vehicles without optional extra SA205 (automatic
transmission):

Tightening torque  11 13 5AZ

.

Installation:

Replace aluminium screws.

If necessary, unfasten screws (4). Remove oil level sensor.

Important!

There must be no adhesive residues in the oil sump retaining
threads.

Clean retaining threads.

Installation:

Replace all seals.

Assemble engine. 

RA  Removing and installing, sealing or replacing oil sump (N52K)

BMW AG - TIS

06.02.2013  01:56

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

14 Housing Cover > < 1 RA Removing And Installing, Sealing Or Replacing Oil Sump (N52K)