64 99 ...

Fault 6.1

Instruction:

Start independent parking heater repeatedly following after-running.

After 32 seconds, measure output of fuel metering pump using peripherals box (pin allocation: refer to DIS circuit
diagram) and vehicle ground.

Specified value:

Voltage switches between 0V and 12V

Question

Measure

Is supply voltage O.K.?

No

Replace independent parking heater
control unit,
refer to 64 12 520

Yes

Start independent parking heater
repeatedly following after-running.
Measure after 32 seconds on the
fuel metering pump.
Specified value as above

No

Repair or replace supply wire from
independent parking heater control
unit to metering pump.

Yes

Replace metering pump,
refer to 64 12 600