Residual heat utilisation restricted
E39 / M47, M57
Complaint:
Shortly after the residual heat function has been activated, cold air flows from the
ventilation nozzles, even though the operating conditions for residual heat utilisation are
met.
The following fringe conditions are required for the residual heat utilisation to function
correctly:
-
Outside temperature less than 15
°
C
-
Engine at normal operating temperature
-
Vehicle battery adequately charged
Cause:
Software error in the air conditioning control panel (IHKA). The auxiliary water pump in the
auxiliary heater is not switched on.
Affected
vehicles:
E39 with M47 or M57 engine, with automatic air conditioning system (option 534), without
independent heating (option 536)
Manufacturing period: September 2000 to March 2001
Procedure:
In case of customer complaint, replace the automatic air conditioning system control panel.
Please refer to Repair Instructions "Removing and installing / replacing heater controls
(automatic air conditioning system)",
RA 64 11 749.
Parts:
Description
Part number
Quantity
IHKA control panel
64 11 6 915 799
1
IHKA control panel (with rear
compartment blower)
64 11 6 915 801
1
Reimbursement:
Material and labour costs incurred can be claimed through the usual warranty channels
subject to current warranty terms.
Defect code
64 11 91 66 00
This defect code is not contained in the official
Defect Code Catalogue but has been included in
the system, thus enabling warranty claims to be
processed.
Within the scope of a visit to the workshop -
Replace IHKA control panel:
Job number
00 52 866
Labour
3 FRUs
In case of order without additional repair
operations -
Replace IHKA control panel:
Job number
00 52 488
SI Residual heat utilisation restricted E39 M47 M57