bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

21 RA Removing And Installing_replacing Changeover Valve For Latent Heat Accumulator|Page 2836 > < 21 RA Removing And Installing_replacing Changeover Valve For Latent Heat Accumulator
Page 2
background image

Unscrew bolt (1). Loosen screws (2).

Lift valve cover upwards to remove.

Unfasten hose clip and pull off hoses (1, 2, and 4).

Unfasten screws and pull changeover valve sideways out of hose
(3).

RA  Removing and installing/replacing changeover valve for latent heat accumulator

BMW AG - TIS

20.02.2013  14:41

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

21 RA Removing And Installing_replacing Changeover Valve For Latent Heat Accumulator|Page 2836 > < 21 RA Removing And Installing_replacing Changeover Valve For Latent Heat Accumulator