24 34 876

Replacing pulse generator (A5S 440Z)

(Driving or turbine speed)

(Oil sump removed)

Pulse generator driving speed:

Release screw, remove retainer (1) and pulse generator (2) from
transmission housing.

Installation:

Tightening torque,

refer to Technical Data 24 34 4AZ.

Disconnect cable plug (1) from pulse generator (2).

Pulse generator turbine speed:

Release screw, remove retainer (1) and pulse generator (2) from
transmission housing.

Installation:

Secure cable to retainer (3).

Tightening torque,

refer to Technical Data 24 34 4AZ.