Release screw, remove retainer (1) and withdraw driving speed
pulse generator (2) from transmission housing.

Installation:

Tightening torque,

refer to Technical Data 24 34 4AZ.

Release screw, remove retainer (1) and withdraw turbine speed
pulse generator (2) from transmission housing.

Release cable from retainer (3).

Installation:

Tightening torque,

refer to Technical Data 24 34 4AZ.

Release cable from retainers.

Disconnect cable plugs (1... 8) from solenoid valves/pressure
regulators.

Remove wiring harness.