64 99 ...

Reading out flashcode

Test precondition:

Check function of independent park heater,

refer to 64 12 005

Instruction:

Connect inspection lamp to glow plug above peripherals box (pin allocation: refer to DIS circuit diagram). Switch on
independent heating via MID or on-board monitor, switch off after 3 minutes running time and, once after-running time

has elapsed, count the number of flash pulses.

Note:

If there is a fault, park heating switches to fault overrun automatically after 2 minutes. 

Flashcode evaluation

Flash pulses

Fault cause and corrective measures

1

Flame detector has short or break,
refer to Fault 02

2

Overvoltage or undervoltage at heater,
charge battery.

3

Temperature sensor has short-circuit,
refer to Fault 05

4

Flame detector defective (does not detect flame),
refer to Fault 02

5

Flame detector defective (always detects flame),
refer to Fault 02

none

Combustion air blower or,
refer to Fault 01
glow plug or,
refer to Fault 03
metering pump defective.
refer to Fault 06

RA  Reading out flashcode