64 12 . . .

Bleeding independant heating
(Thermo Top S)

Special tools required:

17 0 002

17 0 005

Top up coolant.

Fit special tool 17 0 002 /17 0 005  to expansion tank and
develop a pressure of approx. 1.5 bar. Check cooling system for
water leaks when doing so.

Remove microfilter on left.

Open bleeder screw until bubble-free coolant emerges. Close
bleeder screw, undo hose clip.

Start independent parking heater and wait for combustion. Start
engine and run at 4000 rpm. The independent heating system
assumes after-running mode. The circulation pump continues to
operate. Within 2 minutes of starting engine, open and close
bleeder screw on independent heating unit several times. Allow
engine to warm up until thermostat valve opens. This completes
the venting process. Turn off engine, allow to cool down and
check coolant level; if necessary, draw off or top up.