12 42 500
Replacing battery positive lead (M47T2)
Necessary preliminary tasks:
•
Read fault memory of DDE control unit.
•
Switch off ignition
•
Disconnect battery negative lead
•
Remove oil dipstick guide tube
E60, E61
Release screw.
Installation:
Tightening torque 12 42 1AZ
.
Remove battery positive lead (1) from battery positive terminal.
E87, E90
Unfasten nut.
Installation:
Tightening torque 12 42 1AZ
.
Remove battery positive lead (1) from battery positive terminal.
Slacken nut (1).
Installation:
Tightening torque 12 41 4AZ
.
Disconnect battery positive lead (2) from starter motor.