12 42 500

Replacing battery positive lead (M47T2)

Necessary preliminary tasks:

Read fault memory of DDE control unit.

Switch off ignition

Disconnect battery negative lead

Remove oil dipstick guide tube

E60, E61

Release screw.

Installation:

Tightening torque 12 42 1AZ

.

Remove battery positive lead (1) from battery positive terminal.

E87, E90

Unfasten nut.

Installation:

Tightening torque 12 42 1AZ

.

Remove battery positive lead (1) from battery positive terminal.

Slacken nut (1).

Installation:

Tightening torque 12 41 4AZ

.

Disconnect battery positive lead (2) from starter motor.