5 Series E60 520d (M47T2) SAL
Unfasten nut.
Unscrew nuts.
Remove primary catalytic converter (1).
Only if replacing:
Modify holder (1).
Convert exhaust-gas temperature sensor (2).
Installation:
Tightening torque 13 62 1AZ
.
Convert oxygen sensor (3).
Installation:
Tightening torque 11 78 1AZ
Convert pressure sensor (4).