Replacing wiring harness section for ignition
coils (M54)
Necessary preliminary tasks:
•
Read out fault memory of DME control unit.
•
Switch off ignition.
•
Disconnect battery negative lead from battery.
Follow instructions for disconnecting and connecting battery.
•
Remove cover for ignition coils.
•
Remove lower section of microfilter housing on right.
Unfasten screws.
Remove electronics box cover (1).
Installation:
Engage electronics box cover (1) correctly in hinges.
Unlock plug (1) and detach from DME control unit.
Lift wiring harness with profile seals (2) out of partition or
electronics box.
Installation:
To prevent leaks, you must install profile seals (2) correctly.
Unlock and disconnect plug (3).
Detach grounding strap (2) of cable duct from connecting
plates(1) of ignition coils.