5 Series E60 520i (M54) SAL
Important!
Do not place front panel centre section (2) on jump start
terminals.
Do not kink Bowden cables for engine hood locking.
Release screws (1).
Remove front panel centre section (2) in direction of arrow and
place to one side.
Undo screw (1) and feed out refrigerant line (2).
Installation:
Replace sealing rings and moisten with refrigerant oil.
Tightening torque 64 53 6AZ
.
Replacement:
Modify safety pressure switch.
After installation:
•
Evacuate and fill A/C system
RA Replacing line from evaporator to condenser (S85)
BMW AG - TIS
25.01.2013 01:49
Issue status (12/2007) Valid only until next DVD is issued
Copyright