bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

2 RA Replacing Oxygen Control Sensors (N43_ Cylinders 1 And 4 _ Cylinders 2 And 3) > < 1 RA Replacing Lambda Oxygen Monitor Sensor (N43)
Page 2
background image

Release oxygen monitor sensor (1) with special tool  11 7 030
in conjunction with special tool  11 9 150 .

Tightening torque 11 78 1AZ

.

Important!

When using special tool  11 9 150  in conjunction with
special tool  11 7 030 , 47 Nm on torque wrench scale
corresponds to an actual tightening torque of 50 Nm.

Installation:

The thread of the new oxygen monitor sensor is already

coated with Never Seez Compound.

If an oxygen monitor sensor is reused, only apply a thin and

uniform coat of Never Seez Compound (refer
to BMW Parts Service) to thread.

Oxygen monitor sensor section projecting into exhaust

system branch must not be cleaned or come into contact with
lubricant.

Cover oxygen monitor sensor when applying underseal. 

Check function of DME.

RA  Replacing lambda oxygen monitor sensor (N43)

BMW AG - TIS

25.01.2013  15:46

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -