bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

12 Engine Electrical System (M57TU) > < 1 RA Replacing Control Sensor (M57T2)
Page 2
background image

Unclip cable.

Release oxygen sensor (1) with special tool  11 7 020 .

Installation:

Tightening torque 11 78 1AZ

.

Installation:

Threads of new oxygen sensors are already coated with
Never Seez Compound.

If an oxygen sensor is reused, only apply a thin and uniform
coat of Never Seez Compound (refer to BMW Parts
Service) to thread.

Oxygen sensor section projecting into exhaust system branch
must not be cleaned or come into contact with lubricant.

Pay attention to cable routing of oxygen sensors.

Cover oxygen sensors when applying underseal. 

Installation:

Now clear the fault memory.

RA  Replacing control sensor (M57T2)

BMW AG - TIS

11.02.2013  12:13

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

12 Engine Electrical System (M57TU) > < 1 RA Replacing Control Sensor (M57T2)