bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

4 RA Removing And Installing Or Replacing Expansion Valve > < 3 RA Cleaning Evaporator|Page 2728
Page 3
background image

Note:

After rinsing with water, blow out evaporator with spray lance and
air only for approx. 5 minutes. Do this predominantly in the centre
of the evaporator to dry the fan motor behind.

Set heating - A/C system to footwell ventilation and fresh-air
mode. Open windows/doors.

Start car and run heating - A/C system at maximum fan power for
approx. 5 minutes in order to dry heating - A/C system.

In order to eliminate the last remnants of cleaning agent, repeat
this procedure shortly before handover to the customer.

RA  Cleaning evaporator

BMW AG - TIS

20.02.2013  23:08

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 3 -

4 RA Removing And Installing Or Replacing Expansion Valve > < 3 RA Cleaning Evaporator|Page 2728