5 Series E60 530d (M57T2) SAL
Recycling:
Catch and dispose of escaping fuel.
Observe country-specific waste-disposal regulations.
This procedure is applicable to all pressure lines:
Release union nuts (1) on pressure line (2) with special tool
13 5 020 .
Note:
Reset special tool in good time in order to avoid bending pressure
lines.
Installation:
If replacing:
Do not mix up pressure lines!
Installation:
Risk of injector breakage!
Observe tightening torque 13 53 1AZ
without fail.
1.
Hand-tighten all union nuts on pressure lines.
2.
Tighten down union nuts on injectors to specified torque.
3.
Check all components of common rail system for leaks.
RA Replacing all pressure lines (M57T2)
BMW AG - TIS
21.02.2013 12:29
Issue status (12/2007) Valid only until next DVD is issued