Automatic air-recirculation control (IHKA High)

Program for avoiding condensation on the window surfaces (IHKA High only)

Convertible program (E64 only)

Independent ventilation function (IHKA High only)

Independent heater (option 536)

Temperature control

In the heating/air-conditioning system, the air-mass flow is first cooled and dried at the evaporator (provided the
air conditioner is switched on). Then the airflow is heated to the required temperature at the heating system heat
exchanger.

IHKA Basic

The temperature in the heating system heat exchanger is controlled with the help of the heating system
heat exchanger sensor and a pulsed water valve in the heater circuit. The water valve is actuated with a
pulse-modulated signal (PWM signal) by the IHKA control unit. A map for the heating system heat
exchanger determines the opening times for the water valve, depending on the engine speed.

A master controller regulates the temperature inside the vehicle. Regulation is based on the specification
set at the rotary switch (adjustment range: 17-27 

°

C) and the actual value (= interior temperature). 

The lead parameter is derived from the comparison of the actual interior temperature and the corrected
specification (customer setting + ambient temperature). Compared to the set specification, the interior
temperature is raised in the cold so that a comfortable level is achieved even at negative temperatures,
despite the temperature setting being unchanged. The ambient temperature is transmitted through the body
CAN (controller area network) to the IHKA control unit. 
An auxiliary regulating circuit relieves the master controller by eliminating any fault quantities that could be
detected in the heating/air-conditioning system in the form of a temperature change. Disturbances are
caused by: 

Fluctuations in air volume

Fluctuations in coolant flow in engine heater circuit

Temperature changes in fresh air

IHKA High

The separate temperature setting for the driver's side and the front-passenger side affects:

heating system heat exchanger with left/right separation

2 heating system heat exchanger sensors

Dual water valve

The temperature is regulated by 2 master controllers. Regulation is based on the specification set at the
rotary switch and the actual value (= interior temperature). 
Through the left/right separation, 2 auxiliary regulating circuits relieve the two master controllers. 
The solar sensor compensates for additional fault quantities caused by external sources of light or heat
(e.g. direct sunlight).

Note: Reaching maximum outlet temperature in ventilation area. 

The maximum outlet temperature in the ventilation area is reached as follows:

Set the rotary switch for temperature selection to maximum temperature (28 

°

C) 

Set temperature layering as follows with the CID:

IHKA Basic: 
air stratification to "red" (warmer)