5 Series E60 535d (M57TU) SAL
Release screws (2).
Remove vacuum control unit (1) towards top.
Adjust new vacuum control unit with special tool 11 6 300 .
Adjust linkage with nut (1) to length of special tool 11 6 300 .
Secure linkage with lock nut (2).
Function test of turbine control flap, refer to Test module, turbine
control flap.
Check function of DDE.
RA Removing and installing / replacing vacuum control unit for turbine control flap
BMW AG - TIS
22.02.2013 01:56
Issue status (12/2007) Valid only until next DVD is issued