5 Series E60 540i (N62TU) SAL
Installation:
Replace sealing ring (1) and secure with grease.
Drive (2) must be rotated into correct position prior to installation.
Installation:
Align vacuum pump drive to groove (3) on exhaust camshaft.
Vacuum pump can best be installed when groove (3) is vertically
aligned.
If vacuum pump cannot be installed, crank engine if necessary at
central bolt into correct position.
RA Removing and installing/replacing vacuum pump (N62/N62TU)
BMW AG - TIS
22.02.2013 10:06
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 2 -