13 62 604

Replacing pulse generator on left exhaust
camshaft (S85)

(cylinder bank 6 to 10)

Necessary preliminary tasks:

Read out fault memory of DME control unit; if necessary,

work through test schedules

Switch off ignition

Remove left intake filter housing

Remove left ignition coil cover

Release plug connector (1) and pull off.

Release screw.

Remove pulse generator (2).

Installation:

Replace sealing ring and coat with antiseize agent.

Note:

Now clear the fault memory.