bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

3 RA Overview Of Sensors For Airbag System (from 09_2005) > < 2 RA Notes On Scrapping BMW Vehicles With Gas Generators (vehicles With Gateway Modul
Page 2
background image

corresponding cables.

Warning!

Once gas generators have been fired, observe a ventilation period of 10 minutes with the doors opened. Only
then is it permitted to continue work inside the vehicle.

Wear protective goggles and protective gloves when handling a fired gas generator!

The burning of solid fuel will heat up airbag unit - danger of burning hands!

Wash skin with water after contact with fired gas generators!

1. Vehicles with gateway module (all airbags, seat belt tensioners, safety battery terminal)

 

1.1 Expose airbag plug connections.

1.2 Connect "Airbagmaster". For subsequent procedure, refer to SEDA operating instructions.

RA  Notes on scrapping BMW vehicles with gas generators (vehicles with gateway modul

BMW AG - TIS

23.02.2013  08:26

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

3 RA Overview Of Sensors For Airbag System (from 09_2005) > < 2 RA Notes On Scrapping BMW Vehicles With Gas Generators (vehicles With Gateway Modul