Operating sequence for initialization:

Move side window into lower end position.

Press switch into "Open one-touch operation" (second switch

position) for approx. 15 to 25 s and hold down.

Release switch, then immediately press into "Close one-

touch operation" (second switch stage) and hold down.

The side window now moves to the lower end position and

then back to the upper end position.

Initialization is completed once the side window has returned
to the upper end position.

Note:

Carry out function check (one-touch function, anti-trapping
protection and, if necessary, comfort function).