Page 7
background image

If an overvoltage or undervoltage is detected during continuous operation of the button for the electrically pivoted
trailer coupling, the ball head can still be pivoted into the limit position. The ball head's pivoting movement stops
when the button is released. The DC motor can then no longer be energised while the overvoltage or
undervoltage persists.

> E90, E91, E92, E93

The trailer coupling release control unit detects undervoltage and overvoltage.

Undervoltage On-board supply voltage less than 9 volts

Overvoltage On-board supply voltage greater than 15 volts

Outside this voltage range, the system is deactivated.

Overheating protection for drive

> E90, E91, E92, E93

The DC motor is actuated for a maximum of 4 seconds.

The control unit detects an excessively high current draw for the drive, e.g. due to blocking. The maximum
current draw is 13 amps.

Adjusting the trailer coupling

> E60, E61

To ensure that the trailer coupling remains pivoted in the limit position, the DC motor is energised briefly in the
direction of the limit stop every 60 seconds. 

The control unit for the electrically pivoted trailer coupling activates adjustment in the following conditions:

Terminal 15 ON

Ball head pivoted out in limit position

Emergency function

> E60, E61

Cyclical readjustment of the pivoted-out ball head can result in the ball head becoming mechanically jammed in
this limit position. 
In this event, the ball head can be freed from the limit stop by the emergency function.

A defined pivoting movement must be achieved in the run-up phase to pivoting the ball head out or in. This
pivoting movement corresponds to a defined number of Hall-effect pulses by the DC motor. The Hall-effect
pulses are picked up by a Hall-effect sensor on the DC motor. 
If a defined number of Hall-effect pulses is not reached, the control unit activates the emergency function.

In the emergency function, the DC motor is energised five times cyclically (each cycle comprises energising for
300 ms followed by a pause of 200 ms).

If the minimum number of Hall-effect pulses is not achieved, the ball head can then only be pivoted in or out by
continuous operation of the button for the electrically pivoted trailer coupling.

The control unit for the electrically pivoted trailer coupling activates the emergency function in the following
conditions:

Briefly pressing (for less than 1 second) the button for the electrically pivoted trailer coupling (mode: fully
automatic pivoting out or in) 

Trailer head is in the run-up phase to pivoting in or out

Emergency function was not previously triggered

Minimum number of Hall-effect pulses by the DC motor not achieved