5 Series E61 520i (N43) TOUR
12 42 550
Removing and installing/replacing battery
positive lead between starter and jump-start
connection point (N43)
Necessary preliminary tasks:
•
Read out fault memory of DME control unit
•
Switch off ignition
•
Disconnect battery negative lead
•
Follow instructions for disconnecting and connecting battery
•
Remove intake air manifold
Disconnect B+ lead at jump start terminal.
Tightening torque 12 42 2AZ
.
Disconnect B+ lead at starter.
Tightening torque 12 42 10AZ
.
Disconnect B+ lead at alternator.
Tightening torque 12 42 5AZ
.
Note:
Check stored fault messages.
Now clear the fault memory.
RA Removing and installing/replacing battery positive lead between starter and jump
BMW AG - TIS
03.02.2013 16:12
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -