bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

3 RA Cleaning Evaporator|Page 2743 > < 3 RA Cleaning Evaporator
Page 2
background image

Recycling:

Carry out the cleaning operation in a suitable washing bay as the
emerging cleaning agent escapes through the drain openings in
the transmission tunnel.

 

After completing cleaning, allow car to drip-dry for approx. 5
minutes.

Necessary preliminary tasks:

Remove fresh air duct

Partially detach transmission underbody protection (6) for
draining cleaning fluid:

Release screws (2 ... 4) in rear area and press heat shield (5)
away.

Connect special tool 64 1 480  (spray lance) to spraying
equipment.

Insert spray lance (1) through opening (2) to fresh air duct.

By moving spray lance (1) back and forth, spray a uniform
amount of cleaning agent onto evaporator.

RA  Cleaning evaporator

BMW AG - TIS

05.02.2013  16:07

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 2 -

3 RA Cleaning Evaporator|Page 2743 > < 3 RA Cleaning Evaporator