bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

4 RA Removing And Installing Or Replacing Expansion Valve|Page 2745 > < 3 RA Cleaning Evaporator|Page 2743
Page 1
background image

64 51 525

Removing and installing or replacing
expansion valve

Warning!

Risk of injury!

Refrigerant circuit is under high pressure!

Follow safety instructions for handling R 134a refrigerant .

Avoid contact with refrigerant and refrigerant oil.

Follow safety instructions for handling refrigerant oil.

Important!

Risk of damage!

Restart engine only when A/C system has been correctly
filled.

Read and comply with notes on replacing compressor.

Follow instructions for opening and replacing parts in
refrigerant circuit.

If A/C system is opened for more than 24 hours:

Replacing drier insert for A/C system

Necessary preliminary tasks:

Drawing off, evacuating and filling the A/C system are not

included in the time value given for this work operation

Remove fresh air duct

Feed out rubber grommet (1).

Installation:

Make sure rubber grommet (1) is correctly seated.

Slacken nut (2).

Installation:

Tightening torque, 64 53 7AZ.

Detach refrigerant lines (3) and (4) in direction of arrow.

Installation:

RA  Removing and installing or replacing expansion valve

BMW AG - TIS

05.02.2013  16:08

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

4 RA Removing And Installing Or Replacing Expansion Valve|Page 2745 > < 3 RA Cleaning Evaporator|Page 2743