5 Series E61 530xi (N52K) TOUR
12 14 550
Replacing control unit (DME)
Important!
Read and comply with notes on protection against
electrostatic damage (ESD protection).
Necessary preliminary tasks:
•
Read fault memory.
•
Switch off ignition
•
Disconnect battery
•
Remove lower section of microfilter housing on right.
Important!
Follow instructions for removing and installing electronic
control units
Unlock cover (1) with slide (3).
Release bolts (2).
Remove electronics box cover (1).
Installation:
Engage electronics box cover (1) correctly in hinges.
Security version:
Remove DME armour plating.
Unlock and detach all plug connections on DME control unit (1).
Unlock DME control unit (1) and remove.
RA Replacing control unit (DME)
BMW AG - TIS
18.02.2013 14:22
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 1 -