16 11 130
Checking tank cap pressure relief valve
Special tools required:
•
13 3 010
•
16 1 171
•
16 1 172
•
16 1 173
Necessary preliminary tasks:
•
Remove tank cap
Turn pressure regulator on special tool 16 1 171
counterclockwise up to stop.
Connect special tool 16 1 171 via compressed air line (1) to
workshop/garage compressed air system (8...10 bar).
Connect pressure sensor (2) of Diagnosis and Information
System with a measuring range of 0...25 bar.
Select special tool 16 1 172 or 16 1 173 matching vehicle's
filler cap and attach to quick release coupling of special tool
16 1 171 .
Install tank cap on selected special tool.
RA Checking tank cap pressure relief valve
BMW AG - TIS
18.02.2013 14:54
Issue status (12/2007) Valid only until next DVD is issued
Copyright