5 Series E61 535d (M57T2) TOUR
Installation:
Visually inspect shaped sealing ring for correct seating and
damage.
Coat all mounting fittings with anti-friction agent (1). Refer to
Technical Data.
Lock locking clip on pressure pipe (2).
Attach pressure pipe (2) in direction of arrow.
Installation:
VDA coupling is correctly fitted when it snaps into place with an
audible click.
Check function of DDE.
Check pressure pipe for leaks.
Important!
Pressure pipes cannot be fitted without anti-friction agent.
Damaged shaped sealing rings will result in a pressure loss,
risk of damage to turbocharger.
RA Removing and installing/replacing right pressure pipe (charge air hose)
BMW AG - TIS
18.02.2013 19:41
Issue status (12/2007) Valid only until next DVD is issued
Copyright
Page - 2 -