6 Series 630i (N52K) Coupe
64 53 520
Replacing safety pressure switch
Warning!
Risk of injury!
Refrigerant circuit is under high pressure!
Follow safety instructions for handling R 134a refrigerant .
Avoid contact with refrigerant and refrigerant oil.
Follow safety instructions for handling refrigerant oil.
Important!
Risk of damage!
Restart engine only when A/C system has been correctly
filled.
Follow instructions for opening and replacing parts in
refrigerant circuit!
If A/C system is opened for more than 24 hours:Replace
desiccant insert for A/C system
Necessary preliminary tasks:
•
Drawing off, evacuating and filling the A/C system are not
included in the time value given for this work operation
Disconnect plug connection (1).
Release safety pressure switch (2).
Tightening torque 64 53 13AZ
.
RA Replacing safety pressure switch
BMW AG - TIS
16.01.2013 23:09
Issue status (12/2007) Valid only until next DVD is issued