6 Series 630i (N53) Coupe
12 14 524
Replacing pulse generator on exhaust
camshaft (N54)
Important!
Read and comply with notes on protection against
electrostatic damage (ESD protection).
Necessary preliminary tasks:
•
Read out fault memory of DME control unit
•
Switch off ignition
•
Remove fan cowl
Unlock plug (1) and remove.
Release screw.
Tightening torque 12 14 4AZ
.
Remove pulse generator (2).
Note:
Check stored fault messages.
Now clear the fault memory.
RA Replacing pulse generator on exhaust camshaft (N54)
BMW AG - TIS
17.01.2013 11:32
Issue status (12/2007) Valid only until next DVD is issued
Copyright