6 Series E64 645Ci (N62) CONVER
Release control sensor (4) with special tool 11 7 030 in
conjunction with 11 9 150 .
Installation:
Threads of new oxygen sensors are already coated with
Never Seez Compound.
If the oxygen sensor is reused, only apply a thin and uniform coat
of Never Seez Compound (refer to BMW Parts Service) to
thread.
Oxygen sensor section projecting into exhaust system branch
must not be cleaned or come into contact with lubricant.
Installation:
When special tool 11 9 150 is used in conjunction with special
tool 11 7 030 , 47 Nm on the torque wrench dial corresponds
to an actual tightening torque of 50 Nm.
Tighten down control sensor (4) with special tool 11 7 030 in
conjunction with 11 9 150 .
Tightening torque 11 78 1AZ
Pay attention to cable routing of control sensor.
Installation:
Read out fault memory of control unit of Digital Motor Electronics
(DME).
Check stored fault messages.
Rectify faults.
Now clear the fault memory.