Unfasten lock nut (1), pressure screw (2), and nut (3).

Remove pressure plate and air induction tubes.

Installation:

Sealing faces clean and free of debris.

Replace metal gasket.

Installation:

Tighten pressure plate with nut (3).

Preload air induction tubes with pressure screw (2).

For tightening torque,

refer to Technical Data 11 72 2AZ

Secure pressure screw (2) with lock nut.

For tightening torque, 

refer to Technical Data 11 72 2AZ