Place the cable from the repair wiring harness onto the terminal
connector.
Squeeze special tool and push on contact as far as it will go.
Push the terminal connector into the insulation housing and
fasten. Fasten the insulation housing into the bracket.
Pull the connector (x19) from CCM control unit (A4).
RA Repairing front right wiring harness
BMW AG - TIS
03.02.2013 10:40
Issue status (12/2007) Valid only until next DVD is issued