bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

4 RA Fault 04 Circulation Pump > < 2 RA Fault 02 Flame Detector
Page 1
background image

64 99 . . .

Fault 03 Glow plug

Test precondition:

Overheating protection not active. Voltage supply at independent parking heater O.K.

Instruction:

Switch on independent heater via MID or on-board monitor.

Measure voltage of glow plug at peripherals box (pin allocation: refer to DIS circuit diagram).

Specified value: Voltage switches between 0V and 12V

Question

Measure

Is supply voltage O.K.?

No

Replace independent parking heater
control unit,
refer to 64 12 520

Yes

Switch off park heating, remove
connector from glow plug and
measure resistance.
Specified value: 3 

 

±

 1 

Is measured value within valid
range?

No

Replace glow plug,
refer to 64 12 505

Yes

Glow plug is O.K.

RA  Fault 03 Glow plug

BMW AG - TIS

05.02.2013  22:34

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -

4 RA Fault 04 Circulation Pump > < 2 RA Fault 02 Flame Detector