Recycling:

Carry out the cleaning operation in a suitable washing bay as the
emerging cleaning agent escapes through the drain openings in
the transmission tunnel.

 

After completing cleaning, allow car to drip-dry for approx. 5
minutes.

Necessary preliminary tasks:

Remove transmission underbody protection

Move steering column in "top" and "extended" position.

Remove evaporator temperature sensor

Release screw (1).

Remove left footwell air duct (2) in direction of arrow.

Installation:

Make sure air duct in footwell on left (2) is correctly seated on
heating - A/C system (3).

Important!

Risk of damage!

To avoid damaging special tool 64 1 280 , carry out a
function check before starting cleaning.

It must be possible for the folding spray element (1) to be
inserted exactly into guide lug (2) so that special tool  64 1 280
can be guided out of heater without incurring damage.