11 62 140

Removing and installing, sealing or replacing
both exhaust manifolds with catalytic
converter (M54)

Remove intermediate muffler.

Remove reinforcement plate.

Caution!

The section "Removing and installing reinforcement plate"
contains important installation instructions.

Protect stabilizer against paint damage.

Remove retaining bracket and rubber mount from stabilizer.

Detach left and right stabilizer from stabilizer.

Installation:

Replace nuts. Tightening torque 31 35 7AZ.

Note:

The oxygen sensors are in danger of being damaged when the
exhaust manifolds are removed and installed.

Remove oxygen control sensors.

Remove cover for fuel injectors.

Note:

Do not mix up oxygen monitor sensors for cylinders 1 to 3 and
4 to 6 at plug connection to wiring harness.

Mark plug connections.

Unclip the cable from the retainer. Disconnect plug connection.
Unclip cable on rear side of engine from cable guide.

Remove oxygen monitor sensors.