bmw Workshop Repair Guides

BMW Workshop Service and Repair Manuals

1 RA Checking_adjusting Interlock_Shiftlock Function|Page 1079 > < 2 RA Note On Replacing Codable_programmable Control Units
Page 1
background image

25 16 ...

Checking/adjusting Interlock/Shiftlock
function

Adjusting interlock cable:

This task is described in the repair instructions under "Adjusting
interlock cable (Steptronic)".

Checking interlock function:

a)

Ignition key removed or in ignition key position "zero":

Selector lever must not move from "P" position.

b)

Turn ignition key to "ignition" position, press foot brake:

It must be possible to select all selector lever positions.

c)

Selecting all selector lever positions except "P":

 In none of these positions should it be possible to turn the
ignition key back to the "zero" position and remove it.

d)

Move selector lever to "P" position:

It must possible to turn the ignition key back to the "zero"
position and remove it.

Checking shiftlock function:

a)

Ignition on,

Move selector lever to position "P" or "N",

operate foot brake:

Selector lever must unlock.

b)

Start engine,

operate foot brake,

engine speed greater than 2500 rpm:

Selector lever must be locked in position "P" or "N".

c)

Ignition on,

Shift selector lever to position "R",

foot brake released:

In event of brisk shifting from position "R" to "D" and from "D"
to "R", the selector lever must not be locked when position
"N" is exceeded.

If it remains for more than approx. 0.5 secs. in position "N",
the selector lever must be locked.

RA  Checking/adjusting Interlock/Shiftlock function

BMW AG - TIS

06.02.2013  18:52

Issue status (12/2007) Valid only until next DVD is issued

Copyright

Page  - 1 -