61 20 900

Disconnecting and connecting battery
negative lead

Warning!

Observe safety instructions for handling vehicle battery.

Follow instructions for disconnecting and connecting battery

Necessary preliminary tasks:

Open luggage compartment floor panel flap in load area

Remove spare wheel/emergency wheel

Secure removal aid to luggage compartment floor trim panel

If necessary, remove baseplate for emergency wheel

Version with air suspension:

Important!

Risk of damage!

Do not kink, twist or crush pipes.

Release screws (1).

Lay air supply unit (2) with wiring harness and pipes to one side.

Unscrew nut (1).

Tightening torque 61 21 1AZ

.

Detach battery negative lead (2) towards top, lay to one side and
secure.

RA  Disconnecting and connecting battery negative lead